- CMV – continuous mandatory /mechanical/ ventilation
- SCMV – synchronized continuous mechanical ventilation
- PC V – pressure controlled ventilation
- SPCV – synchronized pressure controlled ventilation
- SIMV(V)+PS – volume controlled artificial inspirium with pressure supportSIMV(P)+PS – pressure controlled artificial inspirium with pressure support
- PS – pressure support
- APRV (BIPAP) – airway pressure release ventilation
- 2-Level – two level ventilation (Bilevel, BiPAP, DuoPAP)
- 2-Level+PS – ventilation at two pressure levels with pressure support at both pressure levels
- CPAP – continuous positive airway pressure
- nCPAP – continuous pressure in the respiratory tract at spontaneously ventiled patient, without the weight limit with the nasal application
- PMLV® – programmed multi level ventilation
- HFM CPAP – high frequency modulated CPAP for application at childrem below 5 kg of weight
- APMV® (MVs) – automatic proportional minute volume – self-adaptive regulative system based on maintaining the selected minute ventilation MV
- CFvS® – continuous flow support
- SIGH – Sigh (deep breath)
- PS-VG – pressure support volume guaranted or called PS-CMV
- PC-VG- presssure control volume guarranted
- SIMV-VG – synchronized intermittent mandatory ventilation volume guarranted
- BIPAP (2LV)-VG – two level ventilation volume guarranted
- PMLV®-VG – programmed multi level ventilation volume guarranted
Power supply:
- O2, AIR supply pressure 2,8-6 bar
- max. inspiration flow 240 l.min-1 O2=120 l/min AIR=120 l/min
- electirc power supply TN-S 110 – 240 V, 50/60 Hz
- battery 12 V/ 8 Ah Pb
- running time on own resource at default parameters 4 hours
Ventilation parameters:
- Tidal volume: 2 – 2 000 ml
- breathing frequency: 1 – 180/ min.
- minute ventilation: 0,1 – 35 l/min.
- ratio Ti:Te, %: 10 – 90% ( 1:299 – 9:1)
- inspiration pause: 0 – 75%
- concentration O2: 21 – 100%
- PEEP: 0 – 5 kPa
- Sigh: OFF , OFF,10 to 100 settable by 10
- Inspiration flow: 240 l/min
- Trigger sensitivity: 1 – 20 l/min flow
0,1 – 1,5 kPa pressure
- bias-flow: 1 – 30 l.min-1, OFF
- display: touchscreen 15“ or 21.5″
- O2 Cell – Standard: Galvanic / Optional: Paramagnetic
- pressure – paw,
- tidal volume Vt,
- minute ventilation MV,
- minimal pressure pmin = PEEP,
- medium pressure,
- concentration FiO2
- concentration inspirium/expirium CO2MIN and CO2MAX
- frequency f,
- T/M – activity of patient breathing
- Metabolics of patient
The graphs on the display:
- pressure curve,
- P/V curve
- flow curve,
- Q/V curve
- volumetric curve,
- P/V curve,
- Q/V curve
- CO2 curve
Monitoring the mechanical properties of the lung:
- Time constant period of inspirium and expirium,
- peak alveolar pressure,
- alveolar pressure of end-tidal PEEP,
- alveolar pressure
- Auto PEEP,
- static lung compliance,
- dynamic lung compliance.
- inspiration resistance of airways and ventilation system
• There is implemented a three-level system of alarms
• Alarm system works through sound and light signals to the display and remembering causes
• sophisticated system for extreme situations, allowing when you enter the patient’s weight, to make a quick start appliance in ventilation modes CMV
• Auto-start ventilation system
• Integrated electronic fan provides increased protection against hypoxic mixture
• Secure Electronic Control FiO 2
• When oxygen supply disruption, the device makes the air ventilation from a source of compressed air or external compressor
• on-line monitoring of the mechanical properties of the lung