Ventilation modes:
- CMV – continuous mandatory /mechanical/ ventilation
- SCMV – synchronized continuous mechanical ventilation
- PC V – pressure controlled ventilation
- SPCV – synchronized pressure controlled ventilation
- SIMV(V)+PS – volume controlled artificial inspirium with pressure support
- SIMV(P)+PS – pressure controlled artificial inspirium with pressure support
- PS – pressure support
- APRV (BIPAP) – airway pressure release ventilation
- 2-Level – two level ventilation (Bilevel, BiPAP, DuoPAP)
- 2-Level+PS – ventilation at two pressure levels with pressure support at both pressure levels
- CPAP – continuous positive airway pressure
- MVs (APMV) – minute ventilation servo (automatic proportional minute volume)
- MLV – multi-level ventilation
- CFS – Continuous Flow support
- SIGH – sigh (deep breath)
- PS-VG – pressure support volume guaranted called PS-CMV.
- PC-VG- presssure control volume guarranted
- SIMV-VG – synchronized intermittent mandatory ventilation volume guarranted
- BIPAP (2LV)-VG – two level ventilation volume guarranted
- PMLV®-VG – programmed multi level ventilation volume guarranted
Power supply
- O2 supply pressure 2 – 6 bar
- max. inspiration flow 180l.min-1
- electric power supply TN-S 110 – 240 V, 50/60 Hz
- battery 12 V/ 8 Ah Pb
- minimal of 4 hours for ventilation on internal battery
Ventilation parameters:
- Tidal volume: 10 – 2 000 ml
- breathing frequency: 2 – 80 c.min-1
- minute ventilation: 0,1 – 35 l/min.
- ratio Ti:Te, %: 20 – 80% (1:4 – 4:1)
- inspiration pause: 0 – 50%
- concentration of O2: 21 – 100%
- PEEP: 0 – 35 Pa x100
- Sigh: OFF , OFF,10 to 100 settable by 10
- Inspiration flow: 3- 180 l/min-1
- Trigger sensitivity: 1 – 20 l/min flow
- bias-flow: 1 – 30 l.min-1, OFF
- display: 12.1“ TFT-LCD, optional 15″ touchscreen
- pressure – paw,
- tidal volume Vt,
- minute ventilation MV,
- minimal pressure pmin = PEEP,
- medium pressure,
- concentration FiO2
- concentration inspirium/expirium CO2MIN and CO2MAX
- frequency f,
- T/M – activity of patient breathing
The graphs on the display:
- pressure curve,
- P/V curve
- flow curve,
- Q/V curve
- volumetric curve,
- P/V curve,
- Q/V curve
Monitoring the mechanical properties of the lung on-line:
- Time constant period of inspirium and expirium,
- peak alveolar pressure,
- alveolar pressure of end-tidal PEEP,
- alveolar pressure
- Auto PEEP,
- static lung compliance,
- dynamic lung compliance.
- inspiration resistance of airways and ventilation system
- There is implemented a three-tier system of alarms
- Alarm system works through sound and light signals to the display and remembering causes
- sophisticated system for extreme situations, allowing when you enter the patient’s weight, to make a quick start appliance in ventilation modes CMV
- Integrated electronic multimembrane air generator or turbine (optional) provides increased protection against hypoxic mixture
- Secure Electronic Control FiO 2
- If oxygen supply failed, the device makes ventilation with AIR from the environment
- The minimum period of internal battery – 240 min
- adopted for connection with O2 concentrator